1
/
of
3
Analytix Solutions Catalog
Portable Power Analizer V.3.7 - S
Portable Power Analizer V.3.7 - S
Description
The PS-MEP 3.7 portable electrical variable analyzer is designed to validate energy parameters in low-voltage connections. It is ideal for measurements at critical points in any installation. The device can detect and record a wide range of electrical magnitudes and includes options for LoRaWAN or RS458 sensors to measure and correlate environmental variables such as temperature and humidity.
Key Features
- High-performance embedded computing module
- Designed to correlate multiple data feeds in real-time
- Designed for 24/7 operation
- On-site and Cloud-based real-time data visualization interface
- Internal data storage
- Data security
- Expandable memory and sensors
- Portable and compact design
- Operational robustness
Power Supply
- Voltage Range: 85 – 275 VAC 50/60 Hz
- Maximum Consumption: 15 W
- Minimum Measurement Current: 0.01A (…/5A, …/1A, …/0.250A)
Size and Weight
- Dimensions: 484 x 355 x 171 mm
- Weight: 10 Kg
Environmental Conditions
- Operating Temperature: 0° to 50 °C (32° to 122 °F)
- Storage Temperature: -20° to 60 °C (-4° to 140 °F)
- Operating Humidity: 10…90% (non-condensing)
Certifications
- IP67
- MIL C-4150J
- Def Stan 81-41
- ATA 300
External Backup System (Battery)
- Nominal Voltage: 12 V
- Recommended Nominal Capacity: 5 Ah
- Estimated Duration: 2 hours
System Features and Operational Capacity
- Event Queue System: Handles state changes when communication is lost
- Event Synchronization: Ensures events are synchronized with local time
- On-Site Processing
Synchronization and Communication
- Cloud Sync: Capable of syncing changes from the cloud
- Remote Updates and Commands
- Periodic Data Transmission: Every 10 minutes
Protections
- EMI Filter: Reduces electromagnetic interference
- Overcurrent Fuse
- Surge Protection Device (DPS)
- Phase Protection Breakers
- Short-Circuitable Terminals: For current readings
Inputs
- Digital Input: 1
- Analog Inputs: 2
- RS485 Inputs: 3
- Ethernet RJ45 Ports: 2
- SMA Antenna Connectors: 2
- Backup Battery Connection Port: 1
- Voltage Measurement Inputs: 3
- Current Measurement Inputs: 3 (Rogowski Coils)
Communication Protocols and GSM Bands
- 4G/4G+: LTE-FDD (B1, B2, B3, B4, B5, B7, B8, B28), TDD-LTD (B40)
- 3G: B1, B2, B5, B8
- Protocols: HTTP, TCP/IP, UDP, Wifi, BLE, SNMP, API, SDK, Modbus RS485
- Database Connectors
- Websockets
Applications
- Electrical Network Monitoring
- Power Quality Monitoring
- Energy Efficiency
- Multi-Variable Correlation Analysis
Para mas informaciones y pre-ordenes: info@gssanalytix.com
Share