Skip to product information
1 of 3

Analytix Solutions Catalog

Portable Power Analizer V.3.7 - S

Portable Power Analizer V.3.7 - S

Description

The PS-MEP 3.7 portable electrical variable analyzer is designed to validate energy parameters in low-voltage connections. It is ideal for measurements at critical points in any installation. The device can detect and record a wide range of electrical magnitudes and includes options for LoRaWAN or RS458 sensors to measure and correlate environmental variables such as temperature and humidity.

Key Features

  • High-performance embedded computing module
  • Designed to correlate multiple data feeds in real-time
  • Designed for 24/7 operation
  • On-site and Cloud-based real-time data visualization interface
  • Internal data storage
  • Data security
  • Expandable memory and sensors
  • Portable and compact design
  • Operational robustness

Power Supply

  • Voltage Range: 85 – 275 VAC 50/60 Hz
  • Maximum Consumption: 15 W
  • Minimum Measurement Current: 0.01A (…/5A, …/1A, …/0.250A)

Size and Weight

  • Dimensions: 484 x 355 x 171 mm
  • Weight: 10 Kg

Environmental Conditions

  • Operating Temperature: 0° to 50 °C (32° to 122 °F)
  • Storage Temperature: -20° to 60 °C (-4° to 140 °F)
  • Operating Humidity: 10…90% (non-condensing)

Certifications

  • IP67
  • MIL C-4150J
  • Def Stan 81-41
  • ATA 300

External Backup System (Battery)

  • Nominal Voltage: 12 V
  • Recommended Nominal Capacity: 5 Ah
  • Estimated Duration: 2 hours

System Features and Operational Capacity

  • Event Queue System: Handles state changes when communication is lost
  • Event Synchronization: Ensures events are synchronized with local time
  • On-Site Processing

Synchronization and Communication

  • Cloud Sync: Capable of syncing changes from the cloud
  • Remote Updates and Commands
  • Periodic Data Transmission: Every 10 minutes

Protections

  • EMI Filter: Reduces electromagnetic interference
  • Overcurrent Fuse
  • Surge Protection Device (DPS)
  • Phase Protection Breakers
  • Short-Circuitable Terminals: For current readings

Inputs

  • Digital Input: 1
  • Analog Inputs: 2
  • RS485 Inputs: 3
  • Ethernet RJ45 Ports: 2
  • SMA Antenna Connectors: 2
  • Backup Battery Connection Port: 1
  • Voltage Measurement Inputs: 3
  • Current Measurement Inputs: 3 (Rogowski Coils)

Communication Protocols and GSM Bands

  • 4G/4G+: LTE-FDD (B1, B2, B3, B4, B5, B7, B8, B28), TDD-LTD (B40)
  • 3G: B1, B2, B5, B8
  • Protocols: HTTP, TCP/IP, UDP, Wifi, BLE, SNMP, API, SDK, Modbus RS485
  • Database Connectors
  • Websockets

Applications

  • Electrical Network Monitoring
  • Power Quality Monitoring
  • Energy Efficiency 
  • Multi-Variable Correlation Analysis

 

Para mas informaciones y pre-ordenes: info@gssanalytix.com 

View full details